Reports until 09:53, Sunday 22 March 2020
H1 General (SEI)
camilla.compton@LIGO.ORG - posted 09:53, Sunday 22 March 2020 - last comment - 10:38, Sunday 22 March 2020(55720)
H1 Lockloss 16:41:21 UTC

We were in EQ mode for a 4.8M EQ from Canda. The ground had mostly calmed down when we lost lock, but the high microseism may have contributed.

There is a microseism SEI_CONF state but I'm not sure how that works with the new automatic SEI_ENV. Tagging SEI  to ask what is currently the best state to be in when microseism is high? (Secondary useism: 0.38 μm/s)

Comments related to this report
jim.warner@LIGO.ORG - 10:00, Sunday 22 March 2020 (55722)

This level microseism should not be a problem for the nominal configuration. It needs to be up around 1 micron/s to be an issue. If the microseism gets that high, we will have to do some work on the seismic automation, but we're unlikely to see that kind of ground motion this time of year.

camilla.compton@LIGO.ORG - 10:12, Sunday 22 March 2020 (55723)

Great, thank you Jim. 

camilla.compton@LIGO.ORG - 10:38, Sunday 22 March 2020 (55724)
DRMI is Locked. After 25 minutes verbal alarms asked me to find y-arm by hand. By this time INCREASE_FLASHES had already got flashes to 0.8 and WFS had grabbed. 