Longer coincident observing mode stretches in O3b

Katie Rink, Jess McIver

Summary: Brian Lantz wondered if leap day was a new record. We looked into the duration of coincident H-L observing mode stretches before and after the October commissioning break. Leap day was a new O3 (and likely all-time) H-L coincident observing mode record by more than 16 hours.

In O3a, the longest coincident observing mode stretch was 32.4 hours. In O3b, the longest coincident observing mode stretch was 48.8 hours.

Our main findings are summarized in the table below.

 

L1 O3a

L1 O3b

H1 O3a H1 O3b Both O3a Both O3b
Longest (Hr) 46.4 91.5 44.8 50 32.4 48.8
Average (Hr) 6.2 6.6 6.1 6.5 3.6 3.8

I queried observing mode segments using DMT-ANALYSIS_READY:1 flag for L1 and H1, and the intersection between L1 and H1 in the time span of O3a and O3b independently. O3a was defined as Apr 01 2019 00:00:00 UTC - Oct 01 2019 14:00:00 UTC, O3b was defined as Nov 01 2019 18:00:00 UTC - Mar 23 2020 00:00:00 UTC.

The code I used can be found here.