Displaying report 1-1 of 1.
Reports until 10:33, Tuesday 24 March 2020
H1 TCS
thomas.shaffer@LIGO.ORG - posted 10:33, Tuesday 24 March 2020 (55753)
Accepted TCSY power control calibration in SDF

The TCSY rotation stage was cycling through adjusting power, so I did the usual fix of slightly tweaking the calibration. I changed the power in value from 3.8W to 3.75W 3.65W. One day we will need to get the calibration correct with a full search with this rotation stage.

In SDF there the H1:TCS-TCSY_LASERPOWER_COMMAND channel was flickering as the rot. stage was rerequesting to change powers. I unmonitored this channel.

EDIT: spoke too soon, changed to 3.65W.

Images attached to this report