Nomachine session lists MEDM

The remote desktop nomachine system status is now available as a MEDM screen (see attachment).

The top portion shows the status of the EPICS IOC which is parsing and serving this data.

The lower area shows the current remote desktop session lists and associated statistics. The user list is a duplicate of that provided by the nxserver --list command (see below).

Emprically we found that active sessions have the remote IP field completed and inactive sessions have a dash in this field. This is used to update the active/inactive session counters.

A cronjob on opslogin0 running every minute directs output from the nxserver command and to the /var/run/nomachine_sessions file. The EPICS IOC reads this file once a minute and updates the PVs.

Example nxserver --list output:

Mon Apr  6 13:27:01 PDT 2020
NX> 127 Available sessions:

Display Username         Remote IP  Session ID                       Node           Client Type Client Version Client Platform 
------- ---------------- ---------- -------------------------------- -------------- ----------- -------------- --------------- 
1010    rahul.kumar      10.20.0.17 277A185632085B191523800F801C64DD localhost:4000 GUI         6.9.2          winnt          
1003    cheryl.vorvick   10.20.0.17 627A0180FB63A3D1B52F2BBD803F9966 localhost:4000 GUI         6.9.2          macosx         
1006    cheryl.vorvick   10.20.0.17 68E294E3A9FDCB5DA4A74BB0ACEBAB32 localhost:4000 GUI         6.9.2          macosx         
1018    jim.warner       10.20.0.17 FEF8A3C2FF8B2D967D20E7ED68130435 localhost:4000 GUI         6.9.2          winnt          
1002    david.barker     10.20.0.17 E720AC98E6DDE2BBCEFD704D4994C72E localhost:4000 GUI         6.9.2          macosx         
1005    carlos.perez     -          20CF28AD5B22FC43661265F6248E90DD localhost:4000 FF 68.0     -              notset         
1013    rahul.kumar      10.20.0.17 5FDD7010B4E60FD83A9918A6C16C8BFC localhost:4000 GUI         6.9.2          winnt          
1008    sheila.dwyer     -          F3E3D3DA4DA99924C418AEE497D0FE0D localhost:4000 GUI         6.9.2          winnt          
1004    keita.kawabe     -          D36E4093645839F3393214E9B097C1F2 localhost:4000 GUI         6.9.2          linux          
1020    jonathan.hanks   10.20.0.13 94CCCF41A2F472DAF1CDAFBD38561E5A localhost:4000 GUI         6.9.2          linux          
1014    corey.gray       10.20.0.17 3F4E6EA2CF5C3CE9A6F2E11913714A09 localhost:4000 GUI         6.9.2          macosx         
1019    jenne.driggers   10.20.0.17 F1F0489DCEEC430BFE0CBB28CEF9C291 localhost:4000 GUI         6.9.2          macosx         
1009    thomas.shaffer   -          9CA741CDB0917A072710D6E181B2B1D9 localhost:4000 GUI         6.9.2          macosx         
1015    jim.warner       10.20.0.17 DA24C6AEFC15D05BDE9CE0EE49B800C6 localhost:4000 GUI         6.9.2          winnt          
1007    corey.gray       10.20.0.17 CBF54C8F0B24F2B202A1EC1885FD1526 localhost:4000 GUI         6.9.2          macosx         
1017    david.barker     10.20.0.17 9FC1FCC06CEDD96881312DA1AF64878D localhost:4000 GUI         6.9.2          macosx         
1012    carlos.perez     10.20.0.17 D3D41731F4B82CA73F8D91844124799E localhost:4000 FF 68.0     -              linux          
1016    richard.mccarthy 10.20.0.17 B88BCCA4762EE840A6139B8EA28954B0 localhost:4000 GUI         6.9.2          winnt  

Images attached to this report
Comments related to this report
david.barker@LIGO.ORG - 14:21, Monday 06 April 2020 (55872)

The nomachine MEDM can be opened by a button at the bottom of the Remote Access main MEDM (which in turn is linked from the SITEMAP and the CDS-Overview).

Displaying report 1-1 of 1.