Displaying report 1-1 of 1.
Reports until 12:58, Thursday 16 April 2020
H1 CDS
david.barker@LIGO.ORG - posted 12:58, Thursday 16 April 2020 - last comment - 14:37, Thursday 16 April 2020(55922)
introducing ndshooter, a 'strip shooter' for ndscope trends

In the past we ran a program called stripshooter which captured StripTool images and posted them to the CDS web page. This could not back-fill its data and so could not practically be used to trend months of data.

I have now written its ndscope equivalent, ndshooter. For each YAML file in the userapps/cds/h1/ndshooter directory, the program runs ndscope to a virtual frame buffer and displays the minute trend plot for the look back time specified in the yaml file (minimum of 1 week).

Chandra has requested this system trend certain critical vacuum channels. The attachments below show the trends for the vacuum pressure gauges and LN2 levels.

The vacuum pressure plots show 1 month and 3 month trends for certain LVEA, X-ARM and Y-ARM gauges.

The liquid nitrogen level plots show 1 week and 1 month trends for the cryopumps and external dewars (except CP4).

If other CDS channels should be trended in this way, please send me an email and I can add them to the system.

Vacuum CDS Web Page showing 'live' plots

Images attached to this report
Comments related to this report
david.barker@LIGO.ORG - 14:37, Thursday 16 April 2020 (55923)

All of the current ndshooter trends are collated on the ndshooter.html web page (accessible from the LHO CDS main page). Currently only VAC and PEM-weather are being trended.

ndshooter.html

Displaying report 1-1 of 1.