The transfer function measurements for single stage suspension: OM2, OM3, ZM1 and ZM2 shows that they are healthy and free of any rubbing. Attached below are the plots. The templates of these plots have been updated since the older version (2018) were mistakenly run using low pass ON (CD state): we ran it in low pass Off state. The latest templates are stored at the following locations.
/ligo/svncommon/SusSVN/sus/trunk/HTTS/H1/OM2/SAGM1/Data
2020-04-20_1500_H1SUSOM2_M1_WhiteNoise_L_0p02to50Hz.xml
2020-04-20_1500_H1SUSOM2_M1_WhiteNoise_P_0p02to50Hz.xml
2020-04-20_1500_H1SUSOM2_M1_WhiteNoise_Y_0p02to50Hz.xml
/ligo/svncommon/SusSVN/sus/trunk/HTTS/H1/OM3/SAGM1/Data
2020-04-20_1600_H1SUSOM3_M1_WhiteNoise_L_0p02to50Hz.xml
2020-04-20_1600_H1SUSOM3_M1_WhiteNoise_P_0p02to50Hz.xml
2020-04-20_1600_H1SUSOM3_M1_WhiteNoise_Y_0p02to50Hz.xml
/ligo/svncommon/SusSVN/sus/trunk/HTTS/H1/ZM1/SAGM1/Data
2020-04-20_1800_H1SUSZM1_M1_WhiteNoise_L_0p02to50Hz.xml
2020-04-20_1800_H1SUSZM1_M1_WhiteNoise_P_0p02to50Hz.xml
2020-04-20_1800_H1SUSZM1_M1_WhiteNoise_Y_0p02to50Hz.xml
/ligo/svncommon/SusSVN/sus/trunk/HTTS/H1/ZM2/SAGM1/Data
2020-04-20_2300_H1SUSZM2_M1_WhiteNoise_L_0p02to50Hz.xml
2020-04-20_2300_H1SUSZM2_M1_WhiteNoise_P_0p02to50Hz.xml
2020-04-20_2300_H1SUSZM2_M1_WhiteNoise_Y_0p02to50Hz.xml