I. Michaloliakos, A. Matas, S. Banagiri, J. Ni

In an attempt to identify the source of peaks in the magnetic coupling function of H1, we have investigated the behavior of OSEM channels during weekly magnetic injections at H1 from 10 to 100Hz. The peaks in the magnetic coupling function can be seen in this summary plot from PEM:

https://ldas-jobs.ligo-wa.caltech.edu/~philippe.nguyen/weekly-magnetic-injections/output/2020-03-03/summary.png

We compared the spectra of 287 OSEM channels during magnetic injections to their spectra immediately before and after. We identified the following CS channels that display peaks consistent with those of the magnetic coupling function:

The repository we used to do the data analysis can be found at (https://git.ligo.org/stochastic/magnetic_coupling_resonances), which includes a short wiki that expands on our methodolody. 

Images attached to this report