This morning the IFO was locked on RF while I was taking some OMC scans. The SRC cavity alignment started to drift so I turned off the SRC1Y loop and manually aligned it. A few minutes later we lost lock. Apparently what happened was that SR3 started drfiting quickly.
Now it's position has changed by a few 100 urad according to the osems, although the oplev says it hasn't moved. We still see a beam at the AS port, so the osems must be wrong. The optic is moving around a lot (10s of urad) according to the osems and the oplev, and the beam is moving wildly on the AS camera.
I took the suspension guardian to "safe" and according to the optical lever the motion has quieted down to less than 1 urad, while the osems still see large glitches.
I will attach some plots once I have made some that are easier to read, but this seems like a problem with osems electonics.
Edit to add: LF and RT osems seem to be the problem, as the optic has calmed down with the suspension in safe those two osems are still seeing large glitches. (first attachment)
Second attachment shows what happened at the time of the lockloss.
After a phone call with Richard, Robert went to the floor and power cycled the satelite chassis for SR3 top mass. The attached screenshot shows when it was powered back on RT and SD are still gltiching.
WP 8780
After powercyling the coil drivers for SR3, Sheila reported all channels from the satellite box that are shared by SR3 and SRM are showing no signals. Sat box lost the positive rail and all fault lights were on. Since Robert was onsite he powered down the coil driver and replaced sat box with a spare.
F. Clara, S. Dwyer, R. Schofield
Associated FRS Fault Ticket is 15173.