h1susauxh56 was rebooted to investigate the problem of multiple awgtpman processes running. Only h1iopsusauxh56 was configured to start, two versions of its awgtpman process was found to be running. This problem will be resolved later, for now we need to be vigilant on FE reboots.
The problem of the SUS QUAD models running long was tracked down to the awg process by Alex. We tested this on h1susb6 by running three modified awgtpman processes. We reverted the system back to the original code at the end of this test, so h1susetmy cpu is running long again.
The three new IOP models h1iopsush56, h1iopsusauxh56 and h1iopseih45 were started now that the GDS 64 awg limit was removed by Jim earlier.