Guido M, Joe G, Deepak K
We restored the IMC mirror positions inside their suspension systems based on the Pitch and Yaw OSEM readings to their best lock values (02/10/13 22:20:00). The Pitch/Yaw readings and the Alignment Offsets of the three mirrors are:
MC1:
Alignment Offsets -
Pitch : 355 ct (665.661 urad)
Yaw : 497 ct (1332.258 urad)
Mirror OSEM Value -
Pitch : -2615 urad
Yaw : 46 urad
Length : 80 um
MC2:
Alignment Offsets -
Pitch : 65 ct (121.9 urad)
Yaw : 137 ct (367.8 urad)
Mirror OSEM Value -
Pitch : -21 urad
Yaw : 137 urad
Length : 5 um
MC3:
Alignment Offsets -
Pitch : 543 ct (1018.2 urad)
Yaw : 170 ct (455.7 urad)
Mirror OSEM Value -
Pitch : -855 urad
Yaw : -376 urad
Length : 66 um