After Jeff K created the front end model for OMC (see alog entry 5717) the blank epics values and filters have been filled in for :
-ISI sensor input filters (copied from MC1)
-Offload ouput filters (copied from MC1)
-Osem input filters (copied from MC1)
-OSEM2EUL and EUL2OSEM matrices (calculated with the newly created make_susomcs_projections.m living in /ligo/svncommon/SusSVN/sus/trunk/OMCS/Common/MatlabTools). The lever arms/distances between OSEMS to calculate the matrices have been taken from the drawings attached.
-Coil output filters (copied from MC1)
-Watchdog DC/AC/actuator Band limiters (copied from MC1)
-ISC input filters (copied from MC1)
A new safe.snap (/opt/rtcds/lho/h1/target/h1susomc/h1susomcepics/burt) has been created pointing to the saved snapshot h1susomc_safe.snap (/opt/rtcds/userapps/trunk/sus/h1/burtfiles)
The filter file, the burtsafe file, and the make_susomcsprojection script have been commited on the svn
Still to do : CART2EUL, EUL2CART matrices, and damping filters