Displaying report 1-1 of 1.
Reports until 09:27, Tuesday 12 March 2013
H1 SUS
betsy.weaver@LIGO.ORG - posted 09:27, Tuesday 12 March 2013 - last comment - 10:05, Tuesday 12 March 2013(5757)
PR2 IAS alignment is well underway

Betsy, Travis, Doug, Jason, Arnaud

Yesterday we started the alignment of the PR2 on the HAM3 table.  We made a position adjustment based on the corner cube mdistance measurements by IAS.  We are now working on pitch and yaw.  We also took the opportunity to swap in the shorter top mass blade tip EQ stops.  Arnaud also checked resonance peaks to make sure we were fully suspended after these mechanics were performed.

Comments related to this report
arnaud.pele@LIGO.ORG - 10:05, Tuesday 12 March 2013 (5760)

Something looks to be touching on M3 from the spectra taken.

Displaying report 1-1 of 1.