Displaying report 1-1 of 1.
Reports until 13:34, Thursday 04 February 2021
H1 SUS
rahul.kumar@LIGO.ORG - posted 13:34, Thursday 04 February 2021 - last comment - 07:34, Friday 05 November 2021(57873)
All metal FC1 (A+ HSTS) top to top transfer function results (in air) - all healthy

We investigated the FC1 suspension (after seeing bad Tf results as shown in alog 57843 ) and found a couple of EQ stops faintly rubbing the upper mass. We released the EQ stops and re-adjusted the BOSEMs and then re-took the top to top transfer function measurements. The suspension (all metal) is in air sitting chamber side (near HAM3, connected to PR2) on an optical bench, without AOSEMs.

Attached below are the results for all 6 dof and they look fantastic and free of any rubbing.

Images attached to this report
Non-image files attached to this report
Comments related to this report
jeffrey.kissel@LIGO.ORG - 10:11, Thursday 04 February 2021 (57875)
Nice work!
norna.robertson@LIGO.ORG - 10:34, Thursday 04 February 2021 (57876)SUS

That's good news!

stuart.aston@LIGO.ORG - 18:42, Thursday 04 February 2021 (57878)SUS
TFs look fantastic, and great debugging!
jeffrey.kissel@LIGO.ORG - 11:54, Thursday 04 November 2021 (60528)
These transfer functions were taken with PR2's in-air electronics chain. 
As such, in DTT, when taking these transfer functions, the channel names still come as PR2.
However, in effort to preserve the history of the FC1 *suspensions* data, rather than what the channel name was at the time, I've moved the data that informs this set of plots from where they were saved in 
    /ligo/svncommon/SusSVN/sus/trunk/HSTS/H1/PR2/SAGM1/Data/
to 
    /ligo/svncommon/SusSVN/sus/trunk/HSTS/H1/FC1/SAGM1/Data/
        2021-01-29_1600_H1SUSFC1_M1_WhiteNoise_L_0p01to50Hz.xml
        2021-01-29_1600_H1SUSFC1_M1_WhiteNoise_P_0p01to50Hz.xml
        2021-01-29_1600_H1SUSFC1_M1_WhiteNoise_R_0p01to50Hz.xml
        2021-01-29_1600_H1SUSFC1_M1_WhiteNoise_T_0p01to50Hz.xml
        2021-01-29_1600_H1SUSFC1_M1_WhiteNoise_V_0p01to50Hz.xml
        2021-01-29_1600_H1SUSFC1_M1_WhiteNoise_Y_0p01to50Hz.xml

Similarly, the data was processed and saved by plotHSTS_dtttfs_M1.m, but put in the 
    /ligo/svncommon/SusSVN/sus/trunk/HSTS/H1/PR2/SAGM1/Results/
folder. I've now moved it to 
    /ligo/svncommon/SusSVN/sus/trunk/HSTS/H1/FC1/SAGM1/Results/
        2021-01-29_1600_H1SUSFC1_M1.mat

Finally, I've updated the measurement list in
    /ligo/svncommon/SusSVN/sus/trunk/HSTS/Common/MatlabTools/
         plotallhsts_tfs_M1.m
to reflect this change.
jeffrey.kissel@LIGO.ORG - 14:11, Thursday 04 November 2021 (60529)
Here're the plots from the processing of the "individual" data, which shows cross-coupling and EUL drive to OSEM basis response transfer functions that aren't shown in the multi-measurement comparison plots. 
Non-image files attached to this comment
betsy.weaver@LIGO.ORG - 07:34, Friday 05 November 2021 (60541)

Thank you for continuing to clean up after us, Jeff.

Displaying report 1-1 of 1.