Reports until 20:32, Tuesday 09 March 2021
H1 TCS (AOS)
georgia.mansell@LIGO.ORG - posted 20:32, Tuesday 09 March 2021 - last comment - 09:52, Wednesday 10 March 2021(58162)
CO2 picomotor scan script running overnight

Camilla, TJ, Georgia

Camilla wrote a handy addition to the CO2 power adjust script, which steps the pico on the CO2 periscope mirror while modulating the CO2 power every 5 minutes. I am running this script overnight on my nomachine session.

The script will do picomotor steps of 2000 every 40 minutes. It will step the x pico motor from -10000 steps to -14000, then it will take the x pico back to -10000, and sweep the y pico from -6000 to 8000. (I updated these steps slightly and commited the changes to the svn).

The script lives at /opt/rtcds/userapps/trunk/tcs/common/scripts/power_adj_scripts/co2_power_adjust_inc_pico.py. We've set it to do chops of 2W of CO2 power. It should be done and back at 0W of CO2 power at Mar 10 2021 15:10:33 UTC, which is 7:10am Pacific.

While this script is running please do not change the pico settings on the TCSXCO2 screen. We need pico #3 to stay selected, the speed to stay at walk, and the pico controller to remain enabled.

While this script is running please leave the interferoemter in single bounce ITMX configuration.

 

Comments related to this report
georgia.mansell@LIGO.ORG - 01:09, Wednesday 10 March 2021 (58164)

I miscalculated how long the script would take - it was on track to finish earlier than expected. I added some extra steps, so the picos will sweep down to -20000 in x. The script now should finish at Mar 10 2021 14:23:42 UTC.

camilla.compton@LIGO.ORG - 08:35, Wednesday 10 March 2021 (58166)

Attached is a screenshot of the test and results. We are trying to find pico-motor settings that minimize the 5 minute oscillations caused by the CO2 powering OFF/ON(2W).

The best results for Y are around +6000 at  t = -6h30. The best results for X are maybe -1600 at -1h30, however the overall trend here is moving a fair bit which seems interesting. Possible that the beam is so misaligned its slowly heating a different part of the optic. 

I will move them to this position now, then we can do smaller movements to try and improve this. 

Images attached to this comment
camilla.compton@LIGO.ORG - 08:46, Wednesday 10 March 2021 (58167)

This morning the AS_AIR camera (image attached) also looked clipped and fringed again so this could be the reason for the drifting X and Y camera positions. This was with pico settings X -20000, Y +4000 with IFO still in single bounce configuration (SRM, PRM, ITMY misaligned).

Images attached to this comment