After the recent update of the HLTS and HSTS opticalign sliders (see aLog 5866), I modified a few things for the alignment offsets in BS, ETMY and ITMY.
New sliders range | |||||
Optic | DOF | Range(urad) | Ref document | ||
BS | Pitch | +/-1529 | |||
Yaw | +/-6386 | ||||
QUAD M0-R0 | Pitch | +/-440 | T110595-v2 | ||
Yaw | +/-610 |
New OPTICALIGN gains | |||||
Optic | DOF | Gain (Cts/urad) | Ref document | ||
BS | Pitch | 4.714 | |||
Yaw | 4.268 | ||||
QUAD M0-R0 | Pitch | 23.219 | aLog 4730 | ||
Yaw | 51.689 |
Details :
In order to change the sliders range I modified the OPTICALIGN adl files by opening it with medm in edit mode, and changed the limit of the sliders.
SUS_CUST_BSFM_M1_OPTICALIGN.adl located in /opt/rtcds/userapps/release/sus/common/medm/bsfm for BSFM
SUS_CUST_QUAD_${M0/R0}_OPTICALIGN.adl located in /opt/rtcds/userapps/release/sus/common/medm/quad for ETM/ITM
The files have been commited to the svn as well as the new safe.snap files