Reports until 16:14, Friday 10 September 2021
H1 SQZ
camilla.compton@LIGO.ORG - posted 16:14, Friday 10 September 2021 - last comment - 14:54, Friday 28 January 2022(59866)
HAM7 SQZ Cable Routing update

Keita, Camilla. Follow on from alog 59785. Cable bracket to component SQZ cable status below. Cable document is D1900278. The last cable that attached to the VOPO is #7.

Photos of routing attached, the photos show the cable brackets. Old cable brackets have to be used in some places as the SUS AOSEM cables are old style so do not fit the new brackets.

The plan was to attach all cables to the OPO lid but the cables were stiff enough that it made more sense for some of them to go straight to the SUS support. Cable #11 is cable tied to the OPO, #3 has a secondary cable bracket on the OPO lid, #4 is cable tied to the secondary bracket. #8, #9 go straight to SUS support. 

Cable # Component  Installed CB (planned) Comment 
1 QPD-A N n/a At CIT for assembly.
2 QPD-B n/a At CIT for assembly.
3 This cable splits into four. See 3a-d. Y D2000361 S/N S2101239 CB-5 1st  
3a DCPD-A/B N Secondary 1st

At CIT for assembly. When it arrives it will be plugged into cable bracket D1700307 below DCPD-C/D cable

3b DCPD-C/D Y DCPDs labeled D1600079-V2 003 and 004 Secondary 2nd  
3c Beam Diverter Y D2000361 S/N S2101239 n/a  
3d VOPO lens translation stage Y Cable made by Sheila Secondary on OPO lid  
4 VOPO OPO cavity piezos Y D1700438 S/N S2101231 CB-5 2nd  
5 VOPO SUS AOSEMS (H3,V3) Y D1000234  S/N S1105081 old style near CB-6 (CB-6 3rd)  
6 Picomotors for SK:BS1, SK:M1 N (CB-6 1st) At CIT for testing, expect next week. 
7 VOPO Picomotors for H:M1,HM:2, D:M1, D:M2 (D's not VOPO) (CB-6 2nd) At CIT for testing, expect next week. 
8 VOPO SFI1 Y D1700439 S/N S2101235 CB-5 3rd  
9 VOPO SFI2 Y D1700439 S/N S2101236 CB-5 4th  
10 VOPO SUS AOSEMS (H1,V1, H2, V2) Y  D1000234 S/N 66-910 (?) old style near CB-4 (CB-4 1st)  
11 OPO TEC/Thermistors  Y D1700439 S/N S1700475 CB-4 1st (CB-4 2nd)  
Images attached to this report
Comments related to this report
camilla.compton@LIGO.ORG - 09:36, Wednesday 22 September 2021 (59896)

For ICS assembly see ASSY-D1900278-LHO

Typo above, cable #5 should be D1000239-S1105081

camilla.compton@LIGO.ORG - 09:06, Thursday 16 September 2021 (59929)SEI
6 Picomotors for SK:BS1, SK:M1 D1101516-S2101314 CB-6 1st
7 VOPO Picomotors for H:M1,HM:2, D:M1, D:M2  D1101516-S2101315 CB-6 2nd

Cables #6 and #7 have been installed. We will not plug in SK and D picos until the optics are near their final positions.

The H:M1, H:M2 cables have been routed over the VOPO (see photos 2 and 3). The routing of the H:M2 cable means that CB-6 will need to be closer to the OPOS than expected, nearer the location of the secondary bracket for #3.  This shouldn't be a problem as the #5,6,7 flange to CB cables should have plenty of slack to reach. Will check with Jim- tagging SEI

We had to tilt the L-shaped brackets that hold the pico mighty mouse connectors for H:M1, H:M2 as the optics posts were too short to give the connector enough clearance to point straight down (see photo). This required temporarily removing the black glass clip. We did this carefully so hopefully didn't shift the alignment of the H-path. 

VOPO cable routing is now complete. We plan to balance the OPOS today and install the fibers tomorrow (expect minimal change to balancing) if all goes well.  

Images attached to this comment
camilla.compton@LIGO.ORG - 10:14, Friday 17 September 2021 (59940)

We re-routed the cables before balancing the OPOS (alog 59939) after TJ's advice that having them attached to multiple hard points would have less chance of rubbing. 

See photo attached. We now have both SF1 and SFI2 cables (#8,9) going to the H2, V2 post. h1,v1,h2,v2 aosems and OPO TEC (#10,11) to H1, V1 post (as before) and lens translation, OPO peizo, h3,v3 aosems and both pico cables (#3,4,5,6,7) to H3, V3 post (as before).

Images attached to this comment
camilla.compton@LIGO.ORG - 11:52, Thursday 30 September 2021 (60073)

Adding record of flange to CB cables below.

We decided we need #11 OPO temperature controls next week- once we have the OPO locked in green, use the temperature controls to  make sure that the cavity is also resonant for 1064nm. This cable is being sent from CIT and Jim will install it next week. The #6,7,9 cables for picos and SFI2 are going to be at minimum 3+ weeks out. We decided it's okay to install these at the end and test before closing up. 

Cable #
Component 
Component to CB Installed?
CB to Flange installed?
Comment 
1
QPD-A
N
n/a
CIT for He BOM test (Calum 09/23/21).
2
QPD-B
n/a
CIT for He BOM test (Calum 09/23/21).
3
This cable splits into four. See 3a-d.
Y
 
3a
DCPD-A/B
N
n/a
At CIT for clean and bake (Rich 09/24/21)
3b
DCPD-C/D
n/a
 
3c
Beam Diverter
n/a
 
3d
VOPO lens translation stage
n/a
 
4
VOPO OPO cavity piezos
Y
 
5
VOPO SUS AOSEMS (H3,V3)
Y
 
6
Picomotors for SK:BS1, SK:M1
Y
N
D1700316 260” being manufactured, expected at CIT next week – will need cleaning and testing  (Dean 09/30/21)
7
VOPO Picomotors for H:M1,HM:2, D:M1, D:M2 (D's not VOPO)
Y
N
D1700316 260” being manufactured, expected at CIT next week – will need cleaning and testing  (Dean 09/30/21)
8
VOPO SFI1
Y
 
9
VOPO SFI2
N
D1700316 260” being manufactured, expected at CIT next week – will need cleaning and testing  (Dean 09/30/21)
10
VOPO SUS AOSEMS (H1,V1, H2, V2)
Y  
Y
 
11
OPO TEC/Thermistors 
N
D1700316 120” at CIT being shipped to LHO ready to install  (Dean 09/30/21). Jim will install next week. 
camilla.compton@LIGO.ORG - 15:55, Friday 15 October 2021 (60288)

Last week we installed G:PD1 (DCPA-A) and F:PD1 (DCPD-B). All PDs now tested, working and aligned. Still need to be calibrated and H:PD1's BD positon checked. 

Cable #
Component 
Installed
CB (planned)
Comment 
3a
DCPD-A/B
Cable S2101245, G:PD1 = S2100023 (D1600079-007 D1600079-007), F:PD1 = S2100024 (D1600079-008 D1600079-008)
Secondary CB
Has been routed around the -Y, +X side of the OPO

Remaining HAM7 SQZ cables are QPDs, Picos, SFI2:

Cable #
Component 
Component to CB Installed?
CB to Flange installed?
Comment 
1
QPD-A
N
n/a
CIT, shippment to LHO in 2 weeks (Rich 10/15/21).
2
QPD-B
n/a
CIT, shippment to LHO in 2 weeks (Rich 10/15/21).
3
This cable splits into four. See 3a-d.
Y
 
3a
DCPD-A/B
Y
n/a
 
3b
DCPD-C/D
n/a
 
3c
Beam Diverter
n/a
 
3d
VOPO lens translation stage
n/a
 
4
VOPO OPO cavity piezos
Y
 
5
VOPO SUS AOSEMS (H3,V3)
Y
 
6
Picomotors for SK:BS1, SK:M1
Y
N
D1700316 260” being manufactured, expected at CIT next week – will need cleaning and testing  (Dean 09/30/21)
7
VOPO Picomotors for H:M1,HM:2, D:M1, D:M2 
Y
N
D1700316 260” - see above
8
VOPO SFI1
Y
 
9
VOPO SFI2
N
D1700316 260” - see above
10
VOPO SUS AOSEMS (H1,V1, H2, V2)
Y  
Y
 
11
OPO TEC/Thermistors 
Y -  D1700316-S2101403
 
camilla.compton@LIGO.ORG - 16:52, Monday 13 December 2021 (61031)

This morning Jim and I installed cables #6, 7 and 9 from the roof flange D8 onto the ISI cable brackets.

Cables between cable bracket and component for picomotors SK:BS1, SK:M1, D:M1, D:M2  still need to be connected. This should be done with care so the mirrors aren't bumped- maybe even with laser on to check alignment is kept. The two spare quadrapus cables need to be coiled and secured. Check the pico cable drawing D1101516 and cabling doc  D1900278 for which tentacles to connect. ICS ASSY-D1900278-LHO updated.

Cable # Cable S/N 
6 - Picomotors for SK:BS1, SK:M1 D1700316-V2-00-S2101661
7 - Picomotors for H:M1,HM:2, D:M1, D:M2  D1700316-V2-00-S2101662
9 - VOPO SFI2  D1700316-V2-00-S2101663
camilla.compton@LIGO.ORG - 11:55, Wednesday 15 December 2021 (61076)

Picomotor cables have now been connected to the mirror mounts but not yet tested

Pico cable  Mirror mount
#6 Cable 1 (rightmost, near pin25) SK:BS1
#6 Cable 2 Spare (coiled up with SK:BS1/M1 excess)
#6 Cable 3 SK:M1
#6 Cable 4 Spare (coiled up with SK:BS1/M1 excess)
#7 Cable 1 (rightmost, near pin25) D:M2
#7 Cable 2 D:M1
#7 Cable 3 H:M2
#7 Cable 4 H:M1

To do:

  • The cable bracket these pico cables are in could do with having a dog clamp added to secure it as I could only get one bolt in near the edge. Photo attached. 
  • When finished adding QPDs and SEI weights, more cable ties or peek clamps should be added to secure all cables.

 

Images attached to this comment
camilla.compton@LIGO.ORG - 17:08, Wednesday 26 January 2022 (61467)

Today I added a dog clamp to CB-6 as needed in alog 61076. It is now secure. 

camilla.compton@LIGO.ORG - 14:54, Friday 28 January 2022 (61506)

Picomotors were tested and all working, see alog 61505. I swapped SK:M1 from cable 3 to cable 1. This does now not match the D1900278 cable document but matches the actual cabling.