SUS health checks after Boise EQ - TF measurements for ITMX (looks healthy)

Transfer function measurements for ITMX, with all 6 dof shows that it is free of any rubbing and is healthy. Please find the screenshot attached below. The templates have been stored at the following location,

/ligo/svncommon/SusSVN/sus/trunk/QUAD/H1/ITMX/SAGM0/Data

2020-04-07_1800_H1SUSITMX_M0_WhiteNoise_L_0p01to50Hz.xml

2020-04-07_1800_H1SUSITMX_M0_WhiteNoise_P_0p01to50Hz.xml

2020-04-06_1800_H1SUSITMX_M0_WhiteNoise_R_0p01to50Hz.xml
2020-04-07_1800_H1SUSITMX_M0_WhiteNoise_T_0p01to50Hz.xml
2020-04-07_1800_H1SUSITMX_M0_WhiteNoise_V_0p01to50Hz.xml
2020-04-07_1800_H1SUSITMX_M0_WhiteNoise_Y_0p01to50Hz.xml

Images attached to this report
Comments related to this report
nidhi.patel@LIGO.ORG - 14:09, Friday 10 September 2021 (59867)
Changed file name from 
    2020-04-06_1800_H1SUSITMX_M0_WhiteNoise_R_0p01to50Hz.xml
to
    2020-04-07_1800_H1SUSITMX_M0_WhiteNoise_R_0p01to50Hz.xml

such that it matches the rest of the file name group.