Displaying report 1-1 of 1.
Reports until 07:46, Tuesday 09 April 2013
H1 SEI
hugh.radkins@LIGO.ORG - posted 07:46, Tuesday 09 April 2013 (5995)
LVEA HEPI Pump Station Servo Pressure Adjustment
This morning I found the servo driving the pumps at maximum voltage and only achieving 26.3psi rather than the 28 psi setpoint.  I backed off the setpoint to the usual past 26psi and the drive dropped to ~2000/2048.  Probably a viscosity change from temperature increase.  Seems normal.