Previous alog#60039. Following Nidhi's instructions in T2100415. Closes FAMIS 17463.
| Pressure (in Hg) | Temperature | ||||
|---|---|---|---|---|---|
| Location | Noise | Before | After | Value (deg F) | Location on the Pump |
| CS | OK | 17 | 19 | 155.8 - 159.9 | Pump housing - (took multiple measurements, between 155.8-159.9deg range) |
| EX | OK | 18 | 19 | Within range | All |
| EY | OK | 17.5 | 19 | Within range | All |