New TMTS model
Szymon and Mark B.

We extensively revised the TMTS model using first article data from Ken Mailand. The preferred model is now at

^/trunk/Common/MatlabTools/DoubleModel_Production/tmtsfa.m

In conjunction with the DTT data plotting script

^/trunk/TMTS/Common/MatlabTools/plotTMTS_dtttfs.m

it gives a respectable fit to measured data:

^/trunk/TMTS/H1/TMSY/SAGM1/Results/2013-03-14_1936_H1SUSTMSY_M1.mat
^/trunk/TMTS/H1/TMSY/SAGM1/Results/2013-03-14_1936_H1SUSTMSY_M1_ALL_TFs.pdf

The biggest mismatch is that an R (Mathematica/Matlab pitch) mode predicted for 0.6 Hz is observed at more like 0.7 Hz. Everything else is pretty much bang on.
Non-image files attached to this report
Comments related to this report
mark.barton@LIGO.ORG - 12:40, Wednesday 08 May 2013 (6293)
Per request of Jeff K, the parameter file tmtsfa.m (r4480) was later renamed tmtsopt_firstarticle.m (r4526). 