hugo.paris@LIGO.ORG - posted 18:26, Friday 12 April 2013 - last comment - 14:59, Sunday 14 April 2013(6071)
HAM2-ISI - TF Running

Transfer functions are running over the weekend on HAM2-ISI as well.

HAM2 was unlocked. It was a bit difficult the get the tight covers to stay away from the ISI without the rods we usually have (used on HAM3, see attached pictures). I added a couple clamps to keep the sheet in place over the weekend.

Images attached to this report
Comments related to this report
hugo.paris@LIGO.ORG - 14:59, Sunday 14 April 2013 (6078)

It looks like the covers rubbed against the ISI afterall. We need to take the cover rods from HAM3 chamber, put them on HAM2 and take a new set of measurements.