Displaying report 1-1 of 1.
Reports until 17:06, Monday 13 April 2020
H1 SUS
rahul.kumar@LIGO.ORG - posted 17:06, Monday 13 April 2020 - last comment - 11:54, Monday 29 November 2021(55908)
Health check - triple sus - HLTS (PR3, SR3) and HSTS (PR2)

I have finished taking transfer function measurements for HLTS (PR3, SR3) and HSTS (PR2): all 6 dof. Looking at the attached plots, I can confirm that these three suspensions are healthy and free of any rubbing.

I have stored the templates at the following locations,

/ligo/svncommon/SusSVN/sus/trunk/HLTS/H1/PR3/SAGM1/Data/

2020-04-13_1700_H1SUSPR3_M1_WhiteNoise_L_0p01to50Hz.xml
2020-04-13_1700_H1SUSPR3_M1_WhiteNoise_P_0p01to50Hz.xml
2020-04-13_1700_H1SUSPR3_M1_WhiteNoise_R_0p01to50Hz.xml
2020-04-13_1700_H1SUSPR3_M1_WhiteNoise_T_0p01to50Hz.xml
2020-04-13_1700_H1SUSPR3_M1_WhiteNoise_V_0p01to50Hz.xml
2020-04-13_1700_H1SUSPR3_M1_WhiteNoise_Y_0p01to50Hz.xml

/ligo/svncommon/SusSVN/sus/trunk/HLTS/H1/SR3/SAGM1/Data/

2020-04-13_1800_H1SUSSR3_M1_WhiteNoise_L_0p01to50Hz.xml
2020-04-13_1800_H1SUSSR3_M1_WhiteNoise_P_0p01to50Hz.xml
2020-04-13_1800_H1SUSSR3_M1_WhiteNoise_R_0p01to50Hz.xml
2020-04-13_1800_H1SUSSR3_M1_WhiteNoise_T_0p01to50Hz.xml
2020-04-13_1800_H1SUSSR3_M1_WhiteNoise_V_0p01to50Hz.xml
2020-04-13_1800_H1SUSSR3_M1_WhiteNoise_Y_0p01to50Hz.xml

ligo/svncommon/SusSVN/sus/trunk/HSTS/H1/PR2/SAGM1/Data/

2020-04-13_2200_H1SUSPR2_M1_WhiteNoise_L_0p01to50Hz.xml
2020-04-13_2200_H1SUSPR2_M1_WhiteNoise_P_0p01to50Hz.xml
2020-04-13_2200_H1SUSPR2_M1_WhiteNoise_R_0p01to50Hz.xml
2020-04-13_2200_H1SUSPR2_M1_WhiteNoise_T_0p01to50Hz.xml
2020-04-13_2200_H1SUSPR2_M1_WhiteNoise_V_0p01to50Hz.xml
2020-04-13_2200_H1SUSPR2_M1_WhiteNoise_Y_0p01to50Hz.xml

Images attached to this report
Comments related to this report
jeffrey.kissel@LIGO.ORG - 11:54, Monday 29 November 2021 (60773)
Finally processed this data (as well as the preceding 2018-06-07 data, which was never aLOGged). I concur that PR2 looks healthy during these measurements.