Reports until 18:38, Wednesday 17 April 2013
H1 TCS
greg.grabeel@LIGO.ORG - posted 18:38, Wednesday 17 April 2013 - last comment - 14:37, Friday 19 April 2013(6117)
BSC2 Steering Mirror Assemblies
The two steering mirror assemblies, D1101851, are installed in BSC2. They went in fairly smoothly. One hitch is where the support bracket attaches to the chamber's lower bracket; the weld from the lower bracket to the chamber wall kept the two surfaces from mounting flush.

The two mirrors are NOT installed yet. They oxidized during their bake and I am still working on figuring out if anything should be done about that. The mirrors shed a little, but it seems as though they are not shedding anywhere near the level that the chamber itself is.
Images attached to this report
Comments related to this report
greg.grabeel@LIGO.ORG - 14:37, Friday 19 April 2013 (6143)
Went in today to get better pictures. Specifically you can see where the mating to the chamber is somewhat inhibited by the weld.
Images attached to this comment