WP 10144
Issues reported with decaying signal on SR3, alog 61132. The following was done this afternoon to determine if the issue was a failing OSEM or an electronic issue.
LVEA Rack SUS-R4
1. Disconnected cable going to chamber on the UK Satellite Box
2. Using a DB25 breakout we injected 1V DC in series with a 240K resistor
3. By injecting at the UK Satellite Box the whole electronic chain (Sat Box, Coil Driver, AA Chassis, IO ADC card) could be tested
4. Rahul monitored the corresponding voltage in MEDM
5. CH1 (SUS-R3_M1_OSEMINF_RT_IMMON) resulted in 2000 cts
6. CH2-CH4 resulted in 1600 cts
7. Monitored output of SAT box and all channels gave same readings
SAT Box tested ok, moving on to the CER.
CER Rack SUS-C7
1. Powered down the AA chassis
2. All channels dropped to ~20 counts except for the SUS-R3_M1_OSEMINF_RT_IMMON channel
3. Channel SUS-R3_M1_OSEMINF_RT_IMMON gave a reading of 900 cts
4. Disconnected SCSI cable from AA chassis, reading jumped to 3600 cts
5. Disconnected SCSI cable from IO chassis, reading remained 3600 cts
Will no input on the IO chassis, we get an offset of 3600 cts. Tomorrow IO chassis will be power cycled and if issue persists, ADC card will be replaced.
F. Clara, R. Kumar
Attached below are the screenshots of SR3 M1 stage inmons (RT BOSEM), which shows the 900offset (when AA chassis was powered down) and 3000 offset (when disconnected SCSI cable from AA/IO chassis).
Comments from Richard - We have seen the ~4000 count offset before on channels. I don't recall if it is a blown differential out of the AA or the ribbon into the ADC or the ADC. But this was definitely an issue when we fired up Aligo.
H1SUSH56 "More Info" screen from H1SUSIOPH56 GDS_TP screen indicates that ADC0 (upon which SR3's M1 RT OSEM is read out) shows that it has failed an autocalibration. Attached is a trend of the past month or so's value of the channel that informs the AUTOCAL light, H1:FEC-43_ADC_STAT_0 ("43" because that's H1SUSH56's DCUID, or Front End Computer [FEC] number as per T1400026). One can clearly see that the value changes and holds steady after the Dec 14th "RCG Upgrade Day."