Displaying report 1-1 of 1.
Reports until 17:11, Wednesday 26 January 2022
H1 SQZ
camilla.compton@LIGO.ORG - posted 17:11, Wednesday 26 January 2022 - last comment - 09:02, Tuesday 08 February 2022(61468)
Picomotor chassis for HAM7 and SQZT7 removed as not functioning correctly.

Today Sheila and Georgia removed the HAM7 and SQZT7 Picomotor chassis (located on top of SQZT7) and gave it to Fil and Daniel who are investigating it. It appeared that at least for some drivers the Yaw is functioning but not the Pitch control.

Comments related to this report
camilla.compton@LIGO.ORG - 14:39, Friday 28 January 2022 (61505)

Daniel and Fil fixed/swapped this chassis and Georgia and I tested the HAM7 picomotors. These are currently accessed Sitemap > LSC > Picomotors through the Spare 2 medm rather than the nominal Squeezer HAM7  medm while Daniel fixes a slow controls issue. Tested Pit and Yaw for all HAM7 optics. 

The names on the medm are not correct and should be changed to reflect the below list:

Pico Channel  Optic  MEDM name
1 D:M2 SQZ FC QPD steering 2
2 D:M1 SQZ FC QPD steering 1
3 H:M2 SQZ FC green steering 2
4 H:M1 SQZ FC green steering 1
5 SK:BS1 SQZ FC green beat steering 2
6 SK:M1 SQZ FC green beat steering 1
7 and 8  Did not test - should be SQZT7 waveplates 
camilla.compton@LIGO.ORG - 09:02, Tuesday 08 February 2022 (61655)

Daniel updated these names on the SQZ HAM7 picomotor medm screen and I added a note to the cabling document D1900278.

Displaying report 1-1 of 1.