Sheila, Georgia
Today we measured a few more beam profiles in HAM7 for Lee to put into his mode matching code. We took profiles in 3 locations:
See attached diagram for qualitative locations. For (1) and (3) we took P-SAMS voltage sweeps of ZM2, and for (2) and (3) we measured the beam size at a few different locations. The data is included below (sorry for the mix of distance units!)
|
V_ZM2 [V]
|
V_SG [V]
|
13.5A1 [um]
|
13.5A2 [um]
|
D4sA1 [um]
|
D4sA2 [um]
|
|
100
|
2.74
|
3042
|
3096
|
3146
|
3180
|
|
118
|
3.0
|
2850
|
2726
|
2887
|
2770
|
|
90
|
2.61
|
3163
|
3019
|
3272
|
3238
|
|
V_ZM2 [V]
|
V_SG [V]
|
13.5A1 [um]
|
13.5A2 [um]
|
D4sA1 [um]
|
D4sA2 [um]
|
|
100
|
2.75
|
366
|
380
|
369
|
383
|
|
118
|
3.00
|
396
|
411
|
397
|
413
|
|
80
|
2.5
|
338
|
348
|
340
|
351
|
|
90
|
2.62
|
351
|
363
|
353
|
365
|
|
60
|
2.17
|
301
|
309
|
304
|
312
|
|
30
|
1.61
|
244
|
246
|
252
|
254
|
|
0
|
0.98
|
203
|
201
|
215
|
215
|