Reports until 17:10, Tuesday 22 February 2022
H1 AOS
filiberto.clara@LIGO.ORG - posted 17:10, Tuesday 22 February 2022 - last comment - 09:02, Wednesday 23 February 2022(61839)
Incorrect pin layout in O4 in-air coil driver cables for ZMs (HDS)

WP 10250
FRS 22448

Modified DB9 to DB15 cable pinout for ZM4/ZM5/ZM6. Correct pin layout is shown in D2200034.

Comments related to this report
rahul.kumar@LIGO.ORG - 08:51, Wednesday 23 February 2022 (61850)

Fil, TJ, Rahul

For ZM6 we noticed that there was no (Zero on medm screen) DAQ output in Damped/Robust Damped state, however when you move the suspension to ALIGNED state then you get a normal DAQ output. We are investigating this issue as well.

jeffrey.kissel@LIGO.ORG - 09:02, Wednesday 23 February 2022 (61851)FRS, ISC, SUS
Tagging SUS and ISC.