WP 3820.
I upgraded all four psl models (dbb, fss, iss, pmc) to the latest version. The steps are:
-
check current safe.snap files give no errors (they did not)
-
svn revert the adl files (they were modifed when reverse merged back to an earlier version)
-
svn update the userapps/release/psl
-
make, make-install the models
-
stop the running models, start up the new models
-
check if the existing safe.snaps give errors, only fss could not find some of its channels (iss, pmc, dbb may still be incomplete)
-
restart the DAQ to clear 0x2000 error (incompatible fast ini file) on iss and fss models
First look through the top level medm screens looks good. On the fss screen the RFPD_DC signal is white because this channel has been removed.
I'll hand it over to Michael R for further check out. This closes WP3820
Everything came back up fine as far as I could tell. Servos are all locked. I updated the safe.snap files as well.