locking attempt from yesterday, recycling gain poor

Yesterday there was one attempt at doing teh CARM offset reduction, ndscope shown. At these early stages of lock acquisition, we should not see dips in the reflected power, I think.  When we were in the CARM_150PM state, we had 4 times the single arm build up, but the reflected power had already dipped to 95% of the off resonance power. You can compare this to the plots in 43344 and see that the recycling gain must be low compared to what we've used to lock in the past.  We can attempt to adjust alignment to increase the refl power while we have the arm locked on TR_CARM. 

Images attached to this report
Comments related to this report
sheila.dwyer@LIGO.ORG - 16:17, Friday 04 March 2022 (62067)

In this afternoon's CARM offset reduction attempts we were able to get to the same TR build up with only a 2% dip in REFL, so that is better at least than yesterday.