[Dave Arnaud]
Following Stuart's update of medm screens at LLO, the previous aLogs, and the recent update of medm macro character limit (from 256 to 2048), Dave and I edited the changes on the SITEMAP for all suspensions* at LHO.
-
the /opt/rtcds/userapps/release/sus/common/medm repertory has been svn updated in order to get the text files where the new arguments are defined, eg susetmy_overview_macro.txt
-
SITEMAP.adl in /opt/rtcds/userapps/release/cds/h1/medm arguments has been edited
-
the Arguments column now calls the newly created argument text file the following way :
%(read $(USERAPPS)/sus/common/medm/susetmy_overview_macro.txt),USERAPPS=$(USERAPPS),SITE=LHO,site=lho,IFO=H1,ifo=h1
-
the Display File column calls the overview screen the following way :
$(USERAPPS)/sus/common/medm/quad/SUS_CUST_QUAD_OVERVIEW.adl
*except for ITMX/ETMX/TMSX/BSTST and HAUX
-
An additional susquadtst_macro.txt in /opt/rtcds/userapps/release/sus/common/medm has been created, and updated to the svn