- praxair - bottled water - sprague - reboots to dust monitors - some red alarms - all cleared - work in EX and EY caused some dust - EY IOP State Word went red a few times - PSL env. monitoring went white a few times - no reboots that were run by me - except a reboot of the DAQ around 4PM by VIncent - I discovered that HAM2 and HAM3 had offsets for ISI change yesterday - not me, not Vincent - I put HAM2 and HAM3 optics at their correct slider values and have them damped for alignment check - I have no tests running - lots of work at EY and EX