IFO left in DOWN

Checking in one last time tonight, I noticed that the violin modes were ringing up :(  I don't think that our settings (which work nicely at 50W) are okay for 2W DC readout.  Rather than damp them, I've set the IFO to DOWN.  While unfortunate that I broke the lock, I hope that this prevents the nasty ETMY mode 1 from ringing up any more, and that we won't have to spend another ~3 days damping it. 

First person in in the morning is welcome to try relocking.  Hopefully an alignment isn't needed, but that'll depend on how the IFO feels in the morning.