Displaying report 1-1 of 1.
Reports until 18:23, Tuesday 22 March 2022
H1 ISC
daniel.sigg@LIGO.ORG - posted 18:23, Tuesday 22 March 2022 - last comment - 16:15, Monday 27 February 2023(62310)
New window feature for DCPDs

A new window feature, which computes min/max values over a given time, and then compares them to custiom low/high limits, was installed for the DCPD ADC inputs. This allows an easy way to check for violin modes that are too large.

Images attached to this report
Comments related to this report
thomas.shaffer@LIGO.ORG - 12:33, Friday 01 April 2022 (62436)OpsInfo

I win! I found the screens. To get to to these: SITEMAP -> OMC -> OMC Overview -> IFO DC Readout (black button on the right) -> DCPDs (in upper left corner -> Window A or B

jeffrey.kissel@LIGO.ORG - 16:15, Monday 27 February 2023 (67645)
A lot of the meat of this new window block lives in the c-code MAX_MIN_CALC.c. This code lives in the userapps repo:
    /opt/rtcds/userapps/release/cds/common/src/MAX_MIN_CALC.c
Displaying report 1-1 of 1.