Szymon and Mark B.
We extensively revised the TMTS model using first article data from Ken Mailand. The preferred model is now at
^/trunk/Common/MatlabTools/DoubleModel_Production/tmtsfa.m
In conjunction with the DTT data plotting script
^/trunk/TMTS/Common/MatlabTools/plotTMTS_dtttfs.m
it gives a respectable fit to measured data:
^/trunk/TMTS/H1/TMSY/SAGM1/Results/2013-03-14_1936_H1SUSTMSY_M1.mat
^/trunk/TMTS/H1/TMSY/SAGM1/Results/2013-03-14_1936_H1SUSTMSY_M1_ALL_TFs.pdf
The biggest mismatch is that an R (Mathematica/Matlab pitch) mode predicted for 0.6 Hz is observed at more like 0.7 Hz. Everything else is pretty much bang on.