ETM HWS things to check - generally
A list for posterity:
Beam propagation (how close do we match the design?)
Alignment (how well is our system aligned
have we blocked ITM return beam? [This can confuse interpretation of alignment]
Imaging (how close is our HWS to the conjugate plane of the ETM)
Saturation - make sure the frame rate of the camera is high enough that there are no saturated pixels (with the Hartmann plate installed)
Check the cleanliness of the optics - is there dust on them?
Operation:
Check coupling of tilt to spherical power (does tilting the optic introduce an apparent spherical power signal)?
Check that there is no leakage light from 1064nm (or other wavelengths) into the HWS