The laser power incident on the IMC was increased to 1 W per WP3869.
It will stay at this power level during HIFO.
Preparation
In preparation to increase the power I did the following things:
This dump was something people put to block the beam during the high power adjustment in the last two days.
After the EOM = 1.203 W
In front of the bottom periscope mirror = 167.7 mW
(This was then increased to 1.00 W)
Note that I intentionally misaligned MC2 during the measurement on IOT2L by disabling the pitch offset of 407 urad in M1.
This was because I wanted to avoid fringing in the reflected light.
Adjustments.
The incident power onto the IMC was adjusted to be 1 W by rotating the half-wave-plate in the last attenuation stage in front of the PSL periscope. Note that this rotational stage doesn't give us more than 1.2 W since the power is already limited by another attenuator in the upstream. Then I checked the power on the diodes on IOT2L to make sure they are working OK with the new power level. The power were measured to be :
Length RFPF = 9.3 mW
WFS A = 6 mW
WFS B = 13.6 mW
All of them show reasonably big DC signals in the digital system and seems fine although I didn't check the RF signals yet.