Reports until 14:25, Thursday 09 May 2013
H1 SEI
hugo.paris@LIGO.ORG - posted 14:25, Thursday 09 May 2013 (6314)
HAM-ISI MEDM linked to SUS

The payload screen of the HAM-ISIs now feature links to the MEDM screens of the related suspensions. For example, one can now click on the MC1 button of the HAM2-ISI payload screen, and get re-directed to MC1's MEDM screen. This is especially useful if the suspension(s) tripped the ISI. One can then open the payload sceen, find out which suspension tripped the ISI, and un-trip it in a couple clicks.

 
Details:
- The post-build script that generates the new payload screen was updated from the SVN (create_hamisi_payload_with_links)
- Models were updated to call this new script:
    Call is now: create_hamisi_payload_with_links
    Instead of:  create_hamisi_payload
- Models were recompiled/restarted for both HAM2 and HAM3 ISIs.
- The HAM-ISI MEDM screens were updated from the SVN.
- Unit-specific macro-substitution Text files were created:
    /opt/rtcds/userapps/release/isi/common/medm/hamisi/H1_isiham2_overview_macro.txt
    /opt/rtcds/userapps/release/isi/common/medm/hamisi/H1_isiham3_overview_macro.txt
- The sitemap was updated to call those new text files when performing macro-substitutions.
- Links to the suspension screens were tested and appeared to work correctly.
 
All work performed was commited under the SVN:
/opt/rtcds/userapps/release/isi/h1/models/h1isiham2.mdl                                                         -r4443
/opt/rtcds/userapps/release/isi/h1/models/h1isiham3.mdl                                                        -r4444
/opt/rtcds/userapps/release/isi/common/medm/hamisi/H1_isiham2_overview_macro.txt  -r4446
/opt/rtcds/userapps/release/isi/common/medm/hamisi/H1_isiham3_overview_macro.txt  -r4447
/opt/rtcds/userapps/release/cds/h1/medm/SITEMAP.adl                                                          -r4445
 
WP-3870 is now closed. 
Note: it incorrectly stated that the master model of the HAM-ISI needed to be changed. Ony the top level models needed adjustments. Clarification was added before closing. 
Images attached to this report