re-alignment of IMC : MC2 and MC3 biases changed

I have changed the DC biases on M1s of MC2 and MC3 yesterday for getting a good alignment of the IMC.

Since the IMC was needed to be locked for a short period I just tweaked the two suspensions as this is relatively easy and quick to get a good alignment.

Here are the suspension biases on M1 of MC2 and MC3 before and after my adjustment:

 

/****   BEFORE  (PAST VALUES) *****************************************/

H1:SUS-MC2_M1_OPTICALIGN_Y_OFFSET  =  239

H1:SUS-MC2_M1_OPTICALIGN_P_OFFSET  =  407

 

H1:SUS-MC3_M1_OPTICALIGN_Y_OFFSET  =  -1024

H1:SUS-MC3_M1_OPTICALIGN_P_OFFSET  =  287

 

/****  AFTER (CURRENT VALUES)   *****************************************/

H1:SUS-MC2_M1_OPTICALIGN_Y_OFFSET  =  240

H1:SUS-MC2_M1_OPTICALIGN_P_OFFSET  =  447

 

H1:SUS-MC3_M1_OPTICALIGN_Y_OFFSET  =  -1006

H1:SUS-MC3_M1_OPTICALIGN_P_OFFSET  =  224