Reports until 11:24, Monday 23 May 2022
H1 ISC
sheila.dwyer@LIGO.ORG - posted 11:24, Monday 23 May 2022 - last comment - 10:27, Tuesday 31 May 2022(63274)
low noise locking today

Sheila, Elenna, Jenne, Georgia, Craig, Dhruva, Jeff K

 

Images attached to this report
Comments related to this report
jeffrey.kissel@LIGO.ORG - 18:27, Monday 23 May 2022 (63290)CAL
Tagging CAL for the OMC DPCDs whitening switch from temporarily modified OMC B path back to the well-characterized OMC A path.
Change was in place by 2022-05-23 16:10 UTC (09:10 PDT)

I've just now accepted the change into the SDF system in prep for maintenance -- see attached screenshot.
Images attached to this comment
sheila.dwyer@LIGO.ORG - 10:06, Wednesday 25 May 2022 (63332)

Here is the comparison of the ETMY and ETMY PUM L2P decouplign filters that was promised above. 

Images attached to this comment
sheila.dwyer@LIGO.ORG - 10:27, Tuesday 31 May 2022 (63392)

For the record, the L2P decoupling (and L2Y) was off at ETMY during this time.  I missed this when I first looked at it because the filters were on and had gain, but the matrix which sends the output either right to P or to the P input of drivealign had both elements 0, so the signal wasn't going anywhere.