Reports until 10:12, Tuesday 31 May 2022
H1 CAL (ISC)
jeffrey.kissel@LIGO.ORG - posted 10:12, Tuesday 31 May 2022 - last comment - 10:30, Tuesday 31 May 2022(63391)
2022-05-25 Sensing Function Measurement Complete
J. Kissel
#BelatedALOG

We grabbed a sensing function measurement last Wednesday, 2022-05-25. 

The IFO was in the state described in the "3rd" nominal low noise segment of LHO:63284 i.e. 
   - not yet switched over back to all EX actuation as in LHO:63363, and 
   - EY's L2A filters were still on LHO:63274), 
which may play a role in interpreting the low-frequency end of the processed results (i.e. there may be L2A2L cross-coupling that may confuse any statements about detuning.)

The data were taken after allowing the ADS loops to converge (error signals less than +/-0.05 [ct]), with a hand-installed higher gain (that I think has since been put into lsc_params parameter list of ISC_LOCK of guardian), which took quite a while, so the IFO had been at 50W (PSL input) for at least an hour, and we imagine, thermally stable.

The measurement files have been committed to the repo here:
     /ligo/svncommon/CalSVN/aligocalibration/trunk/Runs/O3/H1/Measurements/FullIFOSensingTFs/
          2022-05-25_H1_DARM_OLGTF_LF_SS_5to1100Hz_15min.xml
          2022-05-25_H1_PCAL2DARMTF_LF_SS_5to1100Hz_10min.xml
          2022-05-25_H1_OMCDCPDSUM_to_DARMIN1.xml

I'm working through creating a new style pyDARM parameter file, then learning how to use the new version of pyDARM, and I'll post processed results when done (see a start in LHO:63334).
Comments related to this report
sheila.dwyer@LIGO.ORG - 10:30, Tuesday 31 May 2022 (63394)

I added a comment to 63274, ETMY length to angle decoupling has been off the whole time.  There still could be some length to angle couplings through the ASC sensors that would cause confusion in the DARM loop, but we have in the past only seen those be important at lower frequencies (less than 2 Hz).