This is an updated table reflecting all work that happened since Oct/2013 including our recent HAM1 incursion. The previous version from Oct/2013 is in alog 7844.
Systems, please update Optics BOM and the drawings in D1000313. Use attached as a reference. M18 needs to be newly added to D1000313 as it wasn't added when they installed REFL LSC_B sensor. M2, M12 and BDV2 need to be merely updated.
Bold font means that the information is not up to date in D1000313. Bold Italic with an underline means that the information in D100313 is not up to date AND it was installed/swapped in the latest incursion.
(Also note that there was a mix-up in the S/N in the old table. The optic we extracted from M2 had a serial number of 0944. In the old table, M2 was supposed to be 0990, OTOH 0944 was supposed to be M15. I don't know the S/N of M15 as of now but assume that it's 0990.)
| ID | Type and DCC | S/N or marking | Mount | Path etc. | comments |
| M1 | 2" 50% IR, E1000671-02 | ? | RH | REFL air-vac splitter. 2nd 50:50 common to LSC/ASC REFL path. | No change. |
| M2 | 2" 50% IR, E1000671-02 | ? | LH, V-dump behind. | REFL vac steering. 3rd 50:50 common to LSC/ASC REFL path. |
New. Used to be HR, E1100048 (ID 0944). AOI is large (larger than 50deg), reflectivity 41% in situ. alog 63544 |
| RM1 | 2" Curved +1.7m HR IR, E1100056-01 | ICS ASSY-D1001396-24 | HTTS | REFL vac MM TT1 | No change. |
| RM2 | 2" Curved -0.6m HR IR, E1100056-03 | ISC ASSY-D1001396-22 | HTTS | REFL vac MM TT2 | No change. |
| M5 | 2" Curved +1.7m HR IR, E1100056-01 | 3 | RH with dump | REFL vac MM fixed | No change. |
| M6 | 2" 50% IR, E040512-B1 (as opposed to E1000671-02) | IO824-01 on the barrel | LH with pico | REFL vac LS/AS splitter. 4th 50:50 common to LSC/ASC REFL path. | No change. |
| M7 | 2" HR IR, E1100048 | ? | LH | REFL air steering | No change. |
| M8 | 2" HR IR/GRN, E1000425 | ? | Peri wth dump | POP/ALS peri | No change. |
| M9 | 2" HR IR/GRN, E1000425 | ? | Peri with dump | POP/ALS peri | No change. |
| M10 | 2" HR IR, HT GRN, E1000669 | ? | LH | POP/ALS dichroic | No change. |
| M11 | 2" HR GRN, E1000652 | ? | LH with dump | ALS steering | No change. |
| M12 | 2" 95% IR, E1000671-v1-02 | ? | LH | POP vac/air splitter | New. Used to be 90:10 (ID IO820-09). alog 63523 |
| M13 | 2" HR IR, E1100048 | ? | RH with dump | PSL reference | No change. |
| M14 | 2" 90% S-pol IR, E040512-B4 | IO823-?? on the barrel | RH | REFL splitter for high power dump | No change. |
| M15 | 2" HR IR, E1100048 | 0990? | RH pico with dump | POP vac steering for LSC | No change. |
| M16 | 2" HR IR, E1100048 | 0965 | RH with dump | POP air steering | No change. |
| M17 | 2" 50:50 IR for P, E1000671 | ? | RH | 1st 50:50 common to LSC/ASC REFL path. | No change. |
| M18 |
2" 50:50 IR for P, E1000671 |
? | RH | LSC REFL A and B splitter. | No change. Doesn't exist in D1000313. |
| M101 | 1" HR IR, E1000595 | ? | 1" LH with dump | part of REFL WFS sled | No change. |
| M102 | 1" HR IR, E1000595 | ? | 1" LH with dump | part of REFL WFS sled | No change. |
| M103 | 1" 50% IR, E1000671-02 | ? | 1" LH pico | part of REFL WFS sled | No change. |
| M104 | 1" HR IR, E1000595 | ? | 1" LH pico with dump | part of REFL WFS sled | No change. |
| L101 | 1" f=+334mm, E1000845-03 | ? | 1" lens | part of REFL WFS sled | No change. |
| L102 | 1" f=-167mm, E1000845-08 | ? | 1" lens | part of REFL WFS sled | No change. |
| L1 | 1" f=+222mm, E1000845-02 | ? | 1" lens | for LSC REFL | No change. |
| L2 | f=+334mm, E1000845-10 | ? | 2" lens | for LSC POP | No change. |
| BDV1 | HR IR, old iLIGO | N/A (no marking) | BDV | for REFL air | No change. |
| BDV2 | HR IR, E1000048 | 2.0-0947 | BDV | for POP air | No change. alog 45279 |
| HW1 | 1" IR half wave plate from ALS stock | N/A (no marking) | rotator mount | for REFL |
No change. |
The IIET tickets that are open to address the "DOCS_NEEDED" call for help in this alog are:
IIET:11724 ECR: Second REFL LSC RF Photodetector
IIET:23545 Attenuate light on in-vac ISC sensors in HAM1