Reports until 16:37, Tuesday 28 June 2022
H1 CDS (DAQ)
david.barker@LIGO.ORG - posted 16:37, Tuesday 28 June 2022 (63748)
CDS Maintenance Summary: Tuesday 28th June 2022

WP10519, 10523 Power Cycle h1susex, replace DAC

Rahul, Erik, Fil, Dave, Tony:

At 09:30 h1susex was powered down. The order was: front end computer, IO Chassis, AA and AI chassis. The power up sequence was AA chassis, IO Chassis, front end then AI chassis.

We found that on restart h1iopsusex was reporting a failed autocal on the first DAC (and 18 bit card). We retested by stopping the models and then running the iop. Again the first 18bit DAC had failed its autocal. Fil took a spare card out and replaced the failed unit.

New Beckhoff Code

Daniel, Dave:

Daniel installed new Beckhoff code this morning, which resulted in modified DAQ INI files for AUX [EX,EY], TCS [EX,EY] and SQZ CS.

DAQ restart

Dave:

The DAQ and the EDC were restarted for the Beckhoff INI changes. h1daqgds1 needed a second restart to sync its channel list.

CER network switch reconfiguration

Fil, Dave:

sw-lvea-aux (which is actually in the CER) was configure to provide three ports to the LVEA serving the workstation network.

Restart/Reboot Log

Tue28Jun2022
LOC TIME HOSTNAME     MODEL/REBOOT
09:51:51 h1susex      ***REBOOT***
09:53:49 h1susex      h1iopsusex  
09:53:56 h1susex      h1susetmx   
09:54:04 h1susex      h1sustmsx   
09:54:11 h1susex      h1susetmxpi 
11:29:57 h1susex      h1iopsusex  
11:56:08 h1susex      ***REBOOT***
11:58:09 h1susex      h1iopsusex  
11:58:16 h1susex      h1susetmx   
11:58:24 h1susex      h1sustmsx   
11:58:31 h1susex      h1susetmxpi 
14:34:18 h1susauxb123 h1edc[[DAQ]]