AS_C whitening restored

Elenna, Evan

AS_C whitening had been turned off a few months ago for violin mode damping and it is now re-engaged (see attachment). The optical signal is at least 20 dB above the ADC noise limit (about 0.01 ct/rtHz) at all frequencies. The input filter modules contain calibration into milliwatts, but the resulting shot noise level does not quite hang together (observed noise seems a factor of a few higher than the expectation from shot noise).

Images attached to this report
Comments related to this report
elenna.capote@LIGO.ORG - 13:55, Friday 22 July 2022 (64111)

Here are AS_C and SRC2 coherences comparing before (all reference trends) and after (all live trends) we turned the AS_C whitening back on.