daniel.sigg@LIGO.ORG - posted 12:37, Tuesday 26 July 2022 - last comment - 10:43, Wednesday 27 July 2022(64150)
New dewhitening filters for HAM-A coil driver of IM1-4, RM1-2, OFI
Fil, Marc, Daniel
Similar to alog 64023, the dewhitening filters of the HAM-A coil drivers were changed for IM1, IM2, IM3, IM4, RM1, RM2 and OFI to provide more high frequency noise suppression.
Comments related to this report
filiberto.clara@LIGO.ORG - 17:09, Tuesday 26 July 2022 (64166)
The IM drivers were using binary channels for run/acquire/enable switching. Since we never use this feature, we now use jumpers instead. The binary IO for these modules is now defunct.
WP 10573
The following units were modified per ECR E2200307 and T2100410. With chassis open, we verified the following on all the units:
A list of the old and newly modified units:
The IM drivers were using binary channels for run/acquire/enable switching. Since we never use this feature, we now use jumpers instead. The binary IO for these modules is now defunct.