Reports until 12:37, Tuesday 26 July 2022
H1 SUS
daniel.sigg@LIGO.ORG - posted 12:37, Tuesday 26 July 2022 - last comment - 10:43, Wednesday 27 July 2022(64150)
New dewhitening filters for HAM-A coil driver of IM1-4, RM1-2, OFI

Fil, Marc, Daniel

Similar to alog 64023, the dewhitening filters of the HAM-A coil drivers were changed for IM1, IM2, IM3, IM4, RM1, RM2 and OFI to provide more high frequency noise suppression.

Comments related to this report
filiberto.clara@LIGO.ORG - 17:09, Tuesday 26 July 2022 (64166)

WP 10573

The following units were modified per ECR E2200307 and T2100410. With chassis open, we verified the following on all the units:

  1. Correct insulators on the regulators (power board) were installed
  2. Verified all output resistors R11/R33 are 1.2Kohm

A list of the old and newly modified units:

IM1 (SM1) Rack SUS-C4, slot U14 Removed S1201156 New S1106043
IM2 (SM2) Rack SUS-C4, slot U13 Removed S1201165 New S1106045
IM3 (PMMT1) Rack SUS-C4, slot U8 Removed S1201162 New S1106048
IM4 (PMMT2) Rack SUS-C4, slot U7 Removed S1201155 New S1200610
RM1 Rack SUS-C4, slot U5 Removed S1200608 New S1200612
RM2 Rack SUS-C4, slot U4 Removed S1200609 New S1200614
OFI Rack SUS-C8, slot U19 Removed S1106042 New S1201156
daniel.sigg@LIGO.ORG - 10:43, Wednesday 27 July 2022 (64171)

The IM drivers were using binary channels for run/acquire/enable switching. Since we never use this feature, we now use jumpers instead. The binary IO for these modules is now defunct.