GV1 Annulus Ion Pump Controller Swapped

I replaced the annulus ion pump controller.  The issue with this system was the ion pump controller did not want to turn on the HV, so tried the DB connector with the shorted pins, did not work.  Swapped it and the ion pump turned on.

GV1 annulus system is pumping on its own, cart was removed on 5/16/2013.  Aux cart was moved to BSC01 annulus ion pump system.