Reports until 17:01, Sunday 07 August 2022
H1 AOS
robert.schofield@LIGO.ORG - posted 17:01, Sunday 07 August 2022 - last comment - 09:31, Friday 26 August 2022(64353)
IR photos of potential scattering noise sites in HAM7

Sheila, Georgia, Dhruva, Robert

The first round of IR photos were swamped by light from the BOSEMs, so Sheila suggsted turning off the coil drivers on the platform. Even with the BOSEMs off, it was a little tricky seeing beam spots that came and went as the beam diverter was opened and closed. With a camera mount on the viewport, I was able to take open/closed pictures that could be precisely overlapped. The first and second pages of Fig1 show photos for diverter closed and open; there are 3 bright spots that are only there when the diverter is open. It is best to view with a pdf viewer that can flip back and forth between pages rather than scroll. The second two pages of the figure shows the "open " picture zoomed into the region with the 3 spots, along with a well lit picture that overlaps with it for optic identification. In addition to the three bright spots, there are a couple of spots that are not as bright.

Non-image files attached to this report
Comments related to this report
sheila.dwyer@LIGO.ORG - 09:57, Monday 08 August 2022 (64360)

The bright spot in the upper right of Robert's image seems to be on B:PD1 (OFI rejected power PD, which is the one we were suspicous of). 

A photo that is helpful to identify the second (from the top) bright spot Robert identified is here: overhead VIP shot, the lens mount that has the bright spot on it is holding an aperture stop as shown here.  The aperature stops aren't shown in the solidworks layout but the diagram on page 8 of T1900649 shows that this aperture stop is intended to catch the p pol beam from the IFO rejected by SFI2, (and a rejected beam from the polarizer for the input to SFI1, on the other side.)

It is more difficult to understand how interferometer light would reach the third spot Robert identified, which seems to be on the edge of G:L1, G:M1, or less likely G:L2.  These optics are labeled here but this photo shows that the as built arrangement is different than the layout with G:L1 moved upstream of G:M1. Another possibility is that the bright spot could be a beam clipping on the actuator for A:M2, but it is also hard to imagine a path for interferometer light to reach there. 

camilla.compton@LIGO.ORG - 09:31, Friday 26 August 2022 (64703)SQZ
There is top down photos of the VOPO platform (taken in the optics lab) in alog 59468.
See the attached copy of the photo for my hypothesis on the third spot of IR light near G:M1. It could be the s-pol light from the IFO getting reflected off the B:L1 aperture stop and onto the G:M1 mirror mount.  IFO s-pol light is deflected off the main path by B:P1 (which is aligned for p-pol light) and the B:L1 aperture stop catchs the s-pol IFO light - comfirmed by Keita in alog 59482.
Optics names on D2000021, but G:L1 and G:L2 actual positions different. 
 
Images attached to this comment