WP10609
Jeff, Fil, Erik, Marc, Jonathan, Dave:
One 18bit-DAC card in each of the h1sush34 and h1sush56 chassis was upgraded to a 20bit-DAC.
| system | card | 18bit-DAC (removed) | 20bit-DAC (installed) |
| h1sush34 | 6th of 6 | 101208-06 | 210303-31 |
| h1sush56 | 5th of 5 | 110425-14 | 210303-28 |
Models changed (no DAQ restart required):
h1iopsush34, h1iosush56, h1sussr2, h1sussrm.
The SWWD receivers for SEI HAM 3,4,5,6,7 were bypassed with a long bypass time (10hours).
The front ends were powered down, the cards were swapped, the new models were installed and the front-ends brought back up.
All watchdogs were removed and Jeff brought the SUS back online.
One surprise was a skipped slot on h1sush34. The 4th slot of its 2nd Adnaco backplane is not being used
Extender type (10b5 8608) Adnaco-Host. Possible V4 or V5 chassis
Card 1
(11c8 0611) Dolphin Interconnect Solutions AS,IX Adapter 611
Card 2
Extender 1
slot 1: (10ee d8c6) Xilinx Corporation,LIGO Timing Board
slot 2: empty
slot 3: (10b5 3101) PLX Technology, Inc.,General Standards 16AI64
slot 4: (10b5 3357) PLX Technology, Inc.,General Standards 18AO8
Card 3
Extender 2
slot 1: (10b5 3101) PLX Technology, Inc.,General Standards 16AI64
slot 2: (10b5 3357) PLX Technology, Inc.,General Standards 18AO8
slot 3: (10b5 3357) PLX Technology, Inc.,General Standards 18AO8
slot 4: empty
Card 4
Extender 3
slot 1: (10b5 3357) PLX Technology, Inc.,General Standards 18AO8
slot 2: (10b5 3357) PLX Technology, Inc.,General Standards 18AO8
slot 3: (10b5 3574) PLX Technology, Inc.,General Standards 20AO8
slot 4: empty
Card 5
Extender 4
slot 1: (1221 8682) Contec Co., Ltd,Digital I/O DIO-64
slot 2: (1221 8682) Contec Co., Ltd,Digital I/O DIO-64
slot 3: empty
slot 4: empty
Extender type (10b5 8608) Adnaco-Host. Possible V4 or V5 chassis
Card 1
(11c8 0611) Dolphin Interconnect Solutions AS,IX Adapter 611
Card 2
Extender 1
slot 1: (10ee d8c6) Xilinx Corporation,LIGO Timing Board
slot 2: empty
slot 3: (10b5 3101) PLX Technology, Inc.,General Standards 16AI64
slot 4: (10b5 3357) PLX Technology, Inc.,General Standards 18AO8
Card 3
Extender 2
slot 1: (10b5 3101) PLX Technology, Inc.,General Standards 16AI64
slot 2: (10b5 3357) PLX Technology, Inc.,General Standards 18AO8
slot 3: (10b5 3357) PLX Technology, Inc.,General Standards 18AO8
slot 4: (10b5 3357) PLX Technology, Inc.,General Standards 18AO8
Card 4
Extender 3
slot 1: (10b5 3574) PLX Technology, Inc.,General Standards 20AO8
slot 2: (10b5 3120) PLX Technology, Inc.,General Standards 16AO16
slot 3: (10b5 3120) PLX Technology, Inc.,General Standards 16AO16
slot 4: empty
Card 5
Extender 4
slot 1: (1221 8682) Contec Co., Ltd,Digital I/O DIO-64
slot 2: (1221 8682) Contec Co., Ltd,Digital I/O DIO-64
slot 3: empty
slot 4: empty
Current card count 18bit-DAC and 20bit-DAC
20bit-DAC count (total: 10)
h1sush34
slot 3: (10b5 3574) PLX Technology, Inc.,General Standards 20AO8
h1susb123
slot 3: (10b5 3574) PLX Technology, Inc.,General Standards 20AO8
slot 4: (10b5 3574) PLX Technology, Inc.,General Standards 20AO8
h1sush56
slot 1: (10b5 3574) PLX Technology, Inc.,General Standards 20AO8
h1susex
slot 3: (10b5 3574) PLX Technology, Inc.,General Standards 20AO8
slot 1: (10b5 3574) PLX Technology, Inc.,General Standards 20AO8
h1susey
slot 3: (10b5 3574) PLX Technology, Inc.,General Standards 20AO8
slot 1: (10b5 3574) PLX Technology, Inc.,General Standards 20AO8
h1sush7
slot 4: (10b5 3574) PLX Technology, Inc.,General Standards 20AO8
slot 1: (10b5 3574) PLX Technology, Inc.,General Standards 20AO8
18bit-DAC count (total: 33)
h1sush2b
slot 4: (10b5 3357) PLX Technology, Inc.,General Standards 18AO8
slot 1: (10b5 3357) PLX Technology, Inc.,General Standards 18AO8
h1sush2a
slot 4: (10b5 3357) PLX Technology, Inc.,General Standards 18AO8
slot 2: (10b5 3357) PLX Technology, Inc.,General Standards 18AO8
slot 3: (10b5 3357) PLX Technology, Inc.,General Standards 18AO8
slot 4: (10b5 3357) PLX Technology, Inc.,General Standards 18AO8
slot 1: (10b5 3357) PLX Technology, Inc.,General Standards 18AO8
slot 2: (10b5 3357) PLX Technology, Inc.,General Standards 18AO8
slot 3: (10b5 3357) PLX Technology, Inc.,General Standards 18AO8
h1oaf0
slot 4: (10b5 3357) PLX Technology, Inc.,General Standards 18AO8
h1sush34
slot 4: (10b5 3357) PLX Technology, Inc.,General Standards 18AO8
slot 2: (10b5 3357) PLX Technology, Inc.,General Standards 18AO8
slot 3: (10b5 3357) PLX Technology, Inc.,General Standards 18AO8
slot 1: (10b5 3357) PLX Technology, Inc.,General Standards 18AO8
slot 2: (10b5 3357) PLX Technology, Inc.,General Standards 18AO8
h1susb123
slot 4: (10b5 3357) PLX Technology, Inc.,General Standards 18AO8
slot 2: (10b5 3357) PLX Technology, Inc.,General Standards 18AO8
slot 4: (10b5 3357) PLX Technology, Inc.,General Standards 18AO8
slot 1: (10b5 3357) PLX Technology, Inc.,General Standards 18AO8
slot 2: (10b5 3357) PLX Technology, Inc.,General Standards 18AO8
slot 3: (10b5 3357) PLX Technology, Inc.,General Standards 18AO8
h1sush56
slot 4: (10b5 3357) PLX Technology, Inc.,General Standards 18AO8
slot 2: (10b5 3357) PLX Technology, Inc.,General Standards 18AO8
slot 3: (10b5 3357) PLX Technology, Inc.,General Standards 18AO8
slot 4: (10b5 3357) PLX Technology, Inc.,General Standards 18AO8
h1susex
slot 4: (10b5 3357) PLX Technology, Inc.,General Standards 18AO8
slot 2: (10b5 3357) PLX Technology, Inc.,General Standards 18AO8
slot 4: (10b5 3357) PLX Technology, Inc.,General Standards 18AO8
h1susey
slot 4: (10b5 3357) PLX Technology, Inc.,General Standards 18AO8
slot 2: (10b5 3357) PLX Technology, Inc.,General Standards 18AO8
slot 4: (10b5 3357) PLX Technology, Inc.,General Standards 18AO8
h1iscex
slot 4: (10b5 3357) PLX Technology, Inc.,General Standards 18AO8
h1iscey
slot 4: (10b5 3357) PLX Technology, Inc.,General Standards 18AO8