Reports until 11:17, Tuesday 09 August 2022
H1 CDS
david.barker@LIGO.ORG - posted 11:17, Tuesday 09 August 2022 - last comment - 15:43, Tuesday 09 August 2022(64386)
Upgrading 18bit-DAC to 20bit-DAC for SUS SR2 and SRM

WP10609

Jeff, Fil, Erik, Marc, Jonathan, Dave:

One 18bit-DAC card in each of the h1sush34 and h1sush56 chassis was upgraded to a 20bit-DAC.

system card 18bit-DAC (removed) 20bit-DAC (installed)
h1sush34 6th of 6 101208-06 210303-31
h1sush56 5th of 5 110425-14 210303-28

Models changed (no DAQ restart required):

h1iopsush34, h1iosush56, h1sussr2, h1sussrm.

The SWWD receivers for SEI HAM 3,4,5,6,7 were bypassed with a long bypass time (10hours).

The front ends were powered down, the cards were swapped, the new models were installed and the front-ends brought back up.

All watchdogs were removed and Jeff brought the SUS back online.

 

Comments related to this report
david.barker@LIGO.ORG - 11:22, Tuesday 09 August 2022 (64388)

One surprise was a skipped slot on h1sush34. The 4th slot of its 2nd Adnaco backplane is not being used

h1sush34 h1sush56
Found 4 bus extenders
Extender type (10b5 8608) Adnaco-Host.  Possible V4 or V5 chassis
Card 1
    (11c8 0611) Dolphin Interconnect Solutions AS,IX Adapter 611
Card 2
    Extender 1
        slot 1: (10ee d8c6) Xilinx Corporation,LIGO Timing Board
        slot 2: empty
        slot 3: (10b5 3101) PLX Technology, Inc.,General Standards 16AI64
        slot 4: (10b5 3357) PLX Technology, Inc.,General Standards 18AO8
Card 3
    Extender 2
        slot 1: (10b5 3101) PLX Technology, Inc.,General Standards 16AI64
        slot 2: (10b5 3357) PLX Technology, Inc.,General Standards 18AO8
        slot 3: (10b5 3357) PLX Technology, Inc.,General Standards 18AO8
        slot 4: empty
Card 4
    Extender 3
        slot 1: (10b5 3357) PLX Technology, Inc.,General Standards 18AO8
        slot 2: (10b5 3357) PLX Technology, Inc.,General Standards 18AO8
        slot 3: (10b5 3574) PLX Technology, Inc.,General Standards 20AO8
        slot 4: empty
Card 5
    Extender 4
        slot 1: (1221 8682) Contec Co., Ltd,Digital I/O DIO-64
        slot 2: (1221 8682) Contec Co., Ltd,Digital I/O DIO-64
        slot 3: empty
        slot 4: empty
 
Found 4 bus extenders
Extender type (10b5 8608) Adnaco-Host.  Possible V4 or V5 chassis
Card 1
    (11c8 0611) Dolphin Interconnect Solutions AS,IX Adapter 611
Card 2
    Extender 1
        slot 1: (10ee d8c6) Xilinx Corporation,LIGO Timing Board
        slot 2: empty
        slot 3: (10b5 3101) PLX Technology, Inc.,General Standards 16AI64
        slot 4: (10b5 3357) PLX Technology, Inc.,General Standards 18AO8
Card 3
    Extender 2
        slot 1: (10b5 3101) PLX Technology, Inc.,General Standards 16AI64
        slot 2: (10b5 3357) PLX Technology, Inc.,General Standards 18AO8
        slot 3: (10b5 3357) PLX Technology, Inc.,General Standards 18AO8
        slot 4: (10b5 3357) PLX Technology, Inc.,General Standards 18AO8
Card 4
    Extender 3
        slot 1: (10b5 3574) PLX Technology, Inc.,General Standards 20AO8
        slot 2: (10b5 3120) PLX Technology, Inc.,General Standards 16AO16
        slot 3: (10b5 3120) PLX Technology, Inc.,General Standards 16AO16
        slot 4: empty
Card 5
    Extender 4
        slot 1: (1221 8682) Contec Co., Ltd,Digital I/O DIO-64
        slot 2: (1221 8682) Contec Co., Ltd,Digital I/O DIO-64
        slot 3: empty
        slot 4: empty
 

 

david.barker@LIGO.ORG - 15:43, Tuesday 09 August 2022 (64400)

Current card count 18bit-DAC and 20bit-DAC

20bit-DAC count (total: 10)

h1sush34
        slot 3: (10b5 3574) PLX Technology, Inc.,General Standards 20AO8
h1susb123
        slot 3: (10b5 3574) PLX Technology, Inc.,General Standards 20AO8
        slot 4: (10b5 3574) PLX Technology, Inc.,General Standards 20AO8
h1sush56
        slot 1: (10b5 3574) PLX Technology, Inc.,General Standards 20AO8
h1susex
        slot 3: (10b5 3574) PLX Technology, Inc.,General Standards 20AO8
        slot 1: (10b5 3574) PLX Technology, Inc.,General Standards 20AO8
h1susey
        slot 3: (10b5 3574) PLX Technology, Inc.,General Standards 20AO8
        slot 1: (10b5 3574) PLX Technology, Inc.,General Standards 20AO8
h1sush7
        slot 4: (10b5 3574) PLX Technology, Inc.,General Standards 20AO8
        slot 1: (10b5 3574) PLX Technology, Inc.,General Standards 20AO8
 

18bit-DAC count (total: 33)

h1sush2b
        slot 4: (10b5 3357) PLX Technology, Inc.,General Standards 18AO8
        slot 1: (10b5 3357) PLX Technology, Inc.,General Standards 18AO8
h1sush2a
        slot 4: (10b5 3357) PLX Technology, Inc.,General Standards 18AO8
        slot 2: (10b5 3357) PLX Technology, Inc.,General Standards 18AO8
        slot 3: (10b5 3357) PLX Technology, Inc.,General Standards 18AO8
        slot 4: (10b5 3357) PLX Technology, Inc.,General Standards 18AO8
        slot 1: (10b5 3357) PLX Technology, Inc.,General Standards 18AO8
        slot 2: (10b5 3357) PLX Technology, Inc.,General Standards 18AO8
        slot 3: (10b5 3357) PLX Technology, Inc.,General Standards 18AO8
h1oaf0
        slot 4: (10b5 3357) PLX Technology, Inc.,General Standards 18AO8
h1sush34
        slot 4: (10b5 3357) PLX Technology, Inc.,General Standards 18AO8
        slot 2: (10b5 3357) PLX Technology, Inc.,General Standards 18AO8
        slot 3: (10b5 3357) PLX Technology, Inc.,General Standards 18AO8
        slot 1: (10b5 3357) PLX Technology, Inc.,General Standards 18AO8
        slot 2: (10b5 3357) PLX Technology, Inc.,General Standards 18AO8
h1susb123
        slot 4: (10b5 3357) PLX Technology, Inc.,General Standards 18AO8
        slot 2: (10b5 3357) PLX Technology, Inc.,General Standards 18AO8
        slot 4: (10b5 3357) PLX Technology, Inc.,General Standards 18AO8
        slot 1: (10b5 3357) PLX Technology, Inc.,General Standards 18AO8
        slot 2: (10b5 3357) PLX Technology, Inc.,General Standards 18AO8
        slot 3: (10b5 3357) PLX Technology, Inc.,General Standards 18AO8
h1sush56
        slot 4: (10b5 3357) PLX Technology, Inc.,General Standards 18AO8
        slot 2: (10b5 3357) PLX Technology, Inc.,General Standards 18AO8
        slot 3: (10b5 3357) PLX Technology, Inc.,General Standards 18AO8
        slot 4: (10b5 3357) PLX Technology, Inc.,General Standards 18AO8
h1susex
        slot 4: (10b5 3357) PLX Technology, Inc.,General Standards 18AO8
        slot 2: (10b5 3357) PLX Technology, Inc.,General Standards 18AO8
        slot 4: (10b5 3357) PLX Technology, Inc.,General Standards 18AO8
h1susey
        slot 4: (10b5 3357) PLX Technology, Inc.,General Standards 18AO8
        slot 2: (10b5 3357) PLX Technology, Inc.,General Standards 18AO8
        slot 4: (10b5 3357) PLX Technology, Inc.,General Standards 18AO8
h1iscex
        slot 4: (10b5 3357) PLX Technology, Inc.,General Standards 18AO8
h1iscey
        slot 4: (10b5 3357) PLX Technology, Inc.,General Standards 18AO8