MC WFS centered

After the PI lockloss, we took a few minutes to center the MC WFS.  I offloaded the WFS using the IMC guardian, took the MC to offline, and used the picos to center.  Pit and yaw seem to be mixed up in either the picos or the WFS DC wiring.  The second attachment shows that the input pointing as seen by IM4 trans and the ISS secondloop QPD haven't moved much. 

Camilla is doing initial alignment now. 

Images attached to this report
Comments related to this report
sheila.dwyer@LIGO.ORG - 09:39, Friday 12 August 2022 (64455)

After recentering the WFS, the noise is improved in the WFS both DC and RF signals as shown in the attached screenshots. 

Images attached to this comment